Request token/refreshtoken:
https://aircheq.eu/gettoken.php?password=...
List of all sensors
https://aircheqonline.nl/getsensordata.php?token=...&list_sensors=1
After 1 hour, use refreshtoken to get a new token:
https://aircheq.eu/gettoken.php?refresh_token=...
Requesting data from a single device
https://aircheq.eu/getsensordata.php?detail=10min&device_id=.....&fromdate=2022-01-28&todate=2022-01-28 15:00&token=…
Requesting data for all devices
https://aircheq.eu/getsensordata.php?detail=10min&fromdate=2022-01-28&todate=2022-01-28 15:00&token=…
To request the most recent data
https://aircheq.eu/getsensordata.php?detail=actual&device_id=.....&token=
The limit is 10 requests per sensor per hour with a minimum of 60 requests per hour
Filter by period:
&fromdate=2023-03-01 15:00&todate=2023-03-01 15:15
Show room names:
&show_room_name=1
Show cost-centers:
&show_cost_center=1
Filter by cost-center
&cost_center=
Filter bydevice_id:
&device_id=
If omitted, returns data for all sensors
Filter by room number
&room_nr=
Data interval:
&detail=actual, 1min, 2min, 3min, 4min, 5min, 10min
Output data: CO2, temperature, rel. humidity, sound, PM1, PM25, PM10, VOC
Locationname, roomnumber, roomname, cost-center